{"product_id":"vacuette®-blood-collection-tube-3-5-ml-serum-separator-gold-cap-sku-454228p","title":"Vacuette® Blood Collection Tube – 3.5 mL Serum Separator, Gold Cap (SKU: 454228P)","description":"\u003ch3 data-start=\"200\" data-end=\"215\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-start=\"217\" data-end=\"564\"\u003eThe \u003cstrong data-start=\"221\" data-end=\"266\"\u003eVacuette® Blood Collection Tube (454228P)\u003c\/strong\u003e from \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eGreiner Bio-One\u003c\/span\u003e\u003c\/span\u003e is a sterile plastic evacuated tube designed for the collection and separation of serum samples. With a \u003cstrong data-start=\"414\" data-end=\"436\"\u003e3.5 mL draw volume\u003c\/strong\u003e, it contains a clot activator and an inert gel separator commonly used in clinical chemistry, serology, and immunology testing.\u003c\/p\u003e\n\u003cp data-start=\"566\" data-end=\"887\"\u003eManufactured from \u003cstrong data-start=\"584\" data-end=\"621\"\u003evirtually unbreakable PET plastic\u003c\/strong\u003e, this tube provides a safer alternative to glass. After centrifugation, the separating gel forms a stable barrier between serum and the clot, preserving sample integrity and stability during transport and storage for up to \u003cstrong data-start=\"845\" data-end=\"857\"\u003e48 hours\u003c\/strong\u003e under appropriate conditions.\u003c\/p\u003e\n\u003chr data-start=\"889\" data-end=\"892\"\u003e\n\u003ch3 data-start=\"894\" data-end=\"912\"\u003eIdentification\u003c\/h3\u003e\n\u003cul data-start=\"914\" data-end=\"1246\"\u003e\n\u003cli data-start=\"914\" data-end=\"978\"\u003e\n\u003cp data-start=\"916\" data-end=\"978\"\u003e\u003cstrong data-start=\"916\" data-end=\"939\"\u003eProduct Identifier:\u003c\/strong\u003e Vacuette® Serum Separator Tube (SST)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"979\" data-end=\"1008\"\u003e\n\u003cp data-start=\"981\" data-end=\"1008\"\u003e\u003cstrong data-start=\"981\" data-end=\"998\"\u003eProduct Code:\u003c\/strong\u003e 454228P\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1009\" data-end=\"1039\"\u003e\n\u003cp data-start=\"1011\" data-end=\"1039\"\u003e\u003cstrong data-start=\"1011\" data-end=\"1021\"\u003eBrand:\u003c\/strong\u003e Greiner Bio-One\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1040\" data-end=\"1062\"\u003e\n\u003cp data-start=\"1042\" data-end=\"1062\"\u003e\u003cstrong data-start=\"1042\" data-end=\"1053\"\u003eVolume:\u003c\/strong\u003e 3.5 mL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1063\" data-end=\"1087\"\u003e\n\u003cp data-start=\"1065\" data-end=\"1087\"\u003e\u003cstrong data-start=\"1065\" data-end=\"1074\"\u003eSize:\u003c\/strong\u003e 13 x 75 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1088\" data-end=\"1135\"\u003e\n\u003cp data-start=\"1090\" data-end=\"1135\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1104\"\u003eCap Color:\u003c\/strong\u003e Gold (with identifying ring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1136\" data-end=\"1187\"\u003e\n\u003cp data-start=\"1138\" data-end=\"1187\"\u003e\u003cstrong data-start=\"1138\" data-end=\"1152\"\u003eAdditives:\u003c\/strong\u003e Clot Activator and Gel Separator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1246\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1246\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1203\"\u003eMaterial:\u003c\/strong\u003e PET Plastic (Polyethylene Terephthalate)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1248\" data-end=\"1251\"\u003e\n\u003ch3 data-start=\"1253\" data-end=\"1269\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul data-start=\"1271\" data-end=\"1708\"\u003e\n\u003cli data-start=\"1271\" data-end=\"1367\"\u003e\n\u003cp data-start=\"1273\" data-end=\"1367\"\u003e\u003cstrong data-start=\"1273\" data-end=\"1293\"\u003eEnhanced Safety:\u003c\/strong\u003e Shatter-resistant PET plastic minimizes breakage and biohazard exposure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1368\" data-end=\"1456\"\u003e\n\u003cp data-start=\"1370\" data-end=\"1456\"\u003e\u003cstrong data-start=\"1370\" data-end=\"1391\"\u003eSample Integrity:\u003c\/strong\u003e Gel barrier prevents remixing of serum and cellular components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1457\" data-end=\"1527\"\u003e\n\u003cp data-start=\"1459\" data-end=\"1527\"\u003e\u003cstrong data-start=\"1459\" data-end=\"1481\"\u003eFaster Turnaround:\u003c\/strong\u003e Clot activator accelerates coagulation time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1528\" data-end=\"1616\"\u003e\n\u003cp data-start=\"1530\" data-end=\"1616\"\u003e\u003cstrong data-start=\"1530\" data-end=\"1549\"\u003eVisual Clarity:\u003c\/strong\u003e Transparent tube allows easy inspection for hemolysis or lipemia\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1617\" data-end=\"1708\"\u003e\n\u003cp data-start=\"1619\" data-end=\"1708\"\u003e\u003cstrong data-start=\"1619\" data-end=\"1644\"\u003eSystem Compatibility:\u003c\/strong\u003e Standard 13 x 75 mm format fits most analyzers and tube racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1710\" data-end=\"1713\"\u003e\n\u003ch3 data-start=\"1715\" data-end=\"1731\"\u003eApplications\u003c\/h3\u003e\n\u003cul data-start=\"1733\" data-end=\"1870\"\u003e\n\u003cli data-start=\"1733\" data-end=\"1763\"\u003e\n\u003cp data-start=\"1735\" data-end=\"1763\"\u003eClinical Chemistry Testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1764\" data-end=\"1785\"\u003e\n\u003cp data-start=\"1766\" data-end=\"1785\"\u003eSerology Analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1786\" data-end=\"1807\"\u003e\n\u003cp data-start=\"1788\" data-end=\"1807\"\u003eImmunology Assays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1808\" data-end=\"1870\"\u003e\n\u003cp data-start=\"1810\" data-end=\"1870\"\u003eTherapeutic Drug Monitoring (verify analyte compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1872\" data-end=\"1875\"\u003e\n\u003ch3 data-start=\"1877\" data-end=\"1897\"\u003eUsage Guidelines\u003c\/h3\u003e\n\u003cul data-start=\"1899\" data-end=\"2372\"\u003e\n\u003cli data-start=\"1899\" data-end=\"1933\"\u003e\n\u003cp data-start=\"1901\" data-end=\"1933\"\u003e\u003cstrong data-start=\"1901\" data-end=\"1912\"\u003eSizing:\u003c\/strong\u003e 3.5 mL draw volume\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1934\" data-end=\"2007\"\u003e\n\u003cp data-start=\"1936\" data-end=\"2007\"\u003e\u003cstrong data-start=\"1936\" data-end=\"1948\"\u003eStorage:\u003c\/strong\u003e Store between 4°C and 25°C; protect from direct sunlight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2008\" data-end=\"2068\"\u003e\n\u003cp data-start=\"2010\" data-end=\"2068\"\u003e\u003cstrong data-start=\"2010\" data-end=\"2023\"\u003eDisposal:\u003c\/strong\u003e Dispose of as regulated biohazardous waste\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2069\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2071\" data-end=\"2083\"\u003e\u003cstrong data-start=\"2071\" data-end=\"2081\"\u003eUsage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-start=\"2086\" data-end=\"2372\"\u003e\n\u003cli data-start=\"2086\" data-end=\"2136\"\u003e\n\u003cp data-start=\"2089\" data-end=\"2136\"\u003ePerform venipuncture using standard technique\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2139\" data-end=\"2193\"\u003e\n\u003cp data-start=\"2142\" data-end=\"2193\"\u003eAllow tube to fill completely (vacuum-controlled)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2196\" data-end=\"2245\"\u003e\n\u003cp data-start=\"2199\" data-end=\"2245\"\u003eGently invert 5–8 times to activate clotting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2248\" data-end=\"2297\"\u003e\n\u003cp data-start=\"2251\" data-end=\"2297\"\u003eAllow sample to clot upright for ~30 minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2300\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2303\" data-end=\"2372\"\u003eCentrifuge per laboratory protocol (e.g., 1800 g for 10–15 minutes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2374\" data-end=\"2377\"\u003e\n\u003ch3 data-start=\"2379\" data-end=\"2441\"\u003eCertifications, Safety Standards, and Regulatory Approvals\u003c\/h3\u003e\n\u003cul data-start=\"2443\" data-end=\"2535\"\u003e\n\u003cli data-start=\"2443\" data-end=\"2465\"\u003e\n\u003cp data-start=\"2445\" data-end=\"2465\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2459\"\u003eCE Marked:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2466\" data-end=\"2490\"\u003e\n\u003cp data-start=\"2468\" data-end=\"2490\"\u003e\u003cstrong data-start=\"2468\" data-end=\"2484\"\u003eFDA Cleared:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2491\" data-end=\"2511\"\u003e\n\u003cp data-start=\"2493\" data-end=\"2511\"\u003e\u003cstrong data-start=\"2493\" data-end=\"2505\"\u003eSterile:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2512\" data-end=\"2535\"\u003e\n\u003cp data-start=\"2514\" data-end=\"2535\"\u003e\u003cstrong data-start=\"2514\" data-end=\"2529\"\u003eLatex Free:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2537\" data-end=\"2540\"\u003e\n\u003ch3 data-start=\"2542\" data-end=\"2581\"\u003eComparison with Competitor Products\u003c\/h3\u003e\n\u003cp data-start=\"2583\" data-end=\"2785\"\u003eComparable in performance to BD Vacutainer® Gold Top SST tubes, Vacuette® tubes feature a \u003cstrong data-start=\"2673\" data-end=\"2705\"\u003etwist or pull-off cap design\u003c\/strong\u003e that many users prefer for safer opening and reduced risk of aerosol formation.\u003c\/p\u003e\n\u003chr data-start=\"2787\" data-end=\"2790\"\u003e\n\u003ch3 data-start=\"2792\" data-end=\"2842\"\u003eTypical User Profile and Application Scenarios\u003c\/h3\u003e\n\u003cul data-start=\"2844\" data-end=\"2899\"\u003e\n\u003cli data-start=\"2844\" data-end=\"2861\"\u003e\n\u003cp data-start=\"2846\" data-end=\"2861\"\u003ePhlebotomists\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2862\" data-end=\"2888\"\u003e\n\u003cp data-start=\"2864\" data-end=\"2888\"\u003eLaboratory Technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2889\" data-end=\"2899\"\u003e\n\u003cp data-start=\"2891\" data-end=\"2899\"\u003eNurses\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2901\" data-end=\"2904\"\u003e\n\u003ch3 data-start=\"2906\" data-end=\"2948\"\u003eBest Practices for Use and Maintenance\u003c\/h3\u003e\n\u003cul data-start=\"2950\" data-end=\"3148\"\u003e\n\u003cli data-start=\"2950\" data-end=\"3043\"\u003e\n\u003cp data-start=\"2952\" data-end=\"3043\"\u003eEnsure tubes are filled to the nominal volume to maintain correct additive-to-blood ratio\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3044\" data-end=\"3148\"\u003e\n\u003cp data-start=\"3046\" data-end=\"3148\"\u003eDo not re-centrifuge SST tubes once the gel barrier has formed, as this may affect analyte stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GREINER","offers":[{"title":"Default Title","offer_id":53233457365152,"sku":"454228P","price":204.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0373\/8579\/7763\/files\/454228P-1.jpg?v=1770321986","url":"https:\/\/www.qpsmedicals.com\/products\/vacuette%c2%ae-blood-collection-tube-3-5-ml-serum-separator-gold-cap-sku-454228p","provider":"QPS Medicals","version":"1.0","type":"link"}